Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Chim Acta ; 1278: 341719, 2023 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-37709430

RESUMO

Red blood cells (RBCs) are the subject of clinical attention due to their biological importance. Recently, it has been shown that certain erythrocyte pathologies could be linked to an abnormal lipid composition. In this work, we have developed a simple and fast method using online sample preparation with liquid chromatography coupled to mass spectrometry (SPE-HPLC-MS/MS), to identify a large number of sphingolipids (SL) and phospholipids (PL). The use of online sample preparation considerably reduces analysis times (15 min including extraction and separation of lipids + 2 min for system re-equilibration) and facilitates experimentation while ensuring very good extraction yields. This method was then successfully applied to the quantification of 30 sphingolipids and phospholipids in plasma and erythrocyte extracts from a cohort of individuals with Gaucher disease, treated or not by enzymotherapy. Our results for the study of this disease, led us to establish the lipid profile of the healthy red blood cells, still not very well-known to date. For this, we adopted a semi-targeted approach, based on the use of a triple-quadrupole analyzer and identified more than two hundred different lipid species. These promising results will hopefully enable us to enrich our knowledge of the normal red blood cells lipidome.


Assuntos
Doença de Gaucher , Espectrometria de Massas em Tandem , Humanos , Cromatografia Líquida de Alta Pressão , Fosfolipídeos , Eritrócitos , Esfingolipídeos
2.
J Cell Mol Med ; 24(17): 9726-9736, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32767726

RESUMO

Gaucher disease (GD) is a genetic disease with mutations in the GBA gene that encodes glucocerebrosidase causing complications such as anaemia and bone disease. GD is characterized by accumulation of the sphingolipids (SL) glucosylceramide (GL1), glucosylsphingosine (Lyso-GL1), sphingosine (Sph) and sphingosine-1-phosphate (S1P). These SL are increased in the plasma of GD patients and the associated complications have been attributed to the accumulation of lipids in macrophages. Our recent findings indicated that red blood cells (RBCs) and erythroid progenitors may play an important role in GD pathophysiology. RBCs abnormalities and dyserythropoiesis have been observed in GD patients. Moreover, we showed higher SL levels in the plasma and in RBCs from untreated GD patients compared with controls. In this study, we quantified SL in 16 untreated GD patients and 15 patients treated with enzyme replacement therapy. Our results showed that the treatment significantly decreases SL levels in the plasma and RBCs. The increased SL content in RBCs correlates with abnormal RBC properties and with markers of disease activity. Because RBCs lack glucocerebrosidase activity, we investigated how lipid overload could occur in these cells. Our results suggested that SL overload in RBCs occurs both during erythropoiesis and during its circulation in the plasma.


Assuntos
Eritrócitos/metabolismo , Doença de Gaucher/sangue , Glucosilceramidase/genética , Esfingolipídeos/sangue , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Criança , Pré-Escolar , Eritropoese/genética , Feminino , Doença de Gaucher/genética , Doença de Gaucher/patologia , Humanos , Lisofosfolipídeos/sangue , Macrófagos/metabolismo , Masculino , Pessoa de Meia-Idade , Psicosina/análogos & derivados , Psicosina/sangue , Esfingosina/análogos & derivados , Esfingosina/sangue , Adulto Jovem
3.
Am J Hematol ; 95(5): 483-491, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31990411

RESUMO

Gaucher disease (GD) is a recessively inherited lysosomal storage disorder in which sphingolipids accumulates in the macrophages that transform into Gaucher cells. A growing body of evidence indicates that red blood cells (RBCs) represent important actors in GD pathophysiology. We previously demonstrated that altered RBC properties including increased Lyso-GL1 levels, dyserythropoiesis, and iron metabolism defect in GD patients contribute to anemia and hyperferritinemia. Since RBC defects also correlated well with markers of GD severity and were normalized under enzyme replacement therapy (ERT), the identification of molecules that are deregulated in GD RBCs represents an important issue in the search of pertinent markers of the disease. Here, we found a decreased expression of the GPI-anchored cell surface protein Semaphorin 7A (Sema7A) in RBCs from untreated GD (GD UT) patients, in parallel with increased levels of the soluble form in the plasma. Sema7A plays a role in neural guidance, atherosclerosis, and inflammatory diseases and represents a promigratory cue in physiological and pathological conditions. We showed that the decreased expression of Sema7A in RBCs correlated with their abnormal properties and with markers of GD activity. Interestingly, ERT restored the level of Sema7A to normal values both in RBCs and in plasma from GD patients. We then proposed that SemaA7A represents a simple and pertinent marker of inflammation in GD. Finally, because Sema7A is known to regulate the activity of immune cells, the increased level of soluble Sema7A in GD patients could propagate inflammation in several tissues.


Assuntos
Doença de Gaucher/tratamento farmacológico , Semaforinas/uso terapêutico , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Estudos Prospectivos , Semaforinas/farmacologia
4.
PLoS One ; 13(11): e0207635, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30452478

RESUMO

Since the early nineties, countless publications have been devoted to the study of possible uses of [60] fullerene (C60) and its derivatives in the fields of materials and nano-biomedical sciences. However, in spite of the importance of conformers notably from the pharmacological point of view, the cis/trans isomerization of C60 mono-adducts has been rarely seldom investigated. Here we present the results of DFT calculations of the structural, vibrational and NMR properties of both cis and trans isomers of fulleropyrrolidine mono-adduct obtained by photo-addition of glycine methyl ester to C60. Taken together, our results have shown that the cis isomer is more stable than the trans one. For the cis conformation, the simulated vibrational spectrum shows a more intense peak at 1298 cm-1. While 13C spectra revealed no significant differences between the two isomers as compared to experimental results, the calculated 1H chemical shifts show a significant difference between the two conformers in both the gas phase and in solution. The trans isomer presents a proton at 5.86 ppm, which is more deshielded than the proton of the cis conformer (5.24 ppm).


Assuntos
Fulerenos/química , Pirrolidinas/química , Espectroscopia de Ressonância Magnética Nuclear de Carbono-13 , Teoria da Densidade Funcional , Isomerismo , Modelos Moleculares , Conformação Molecular , Espectroscopia de Prótons por Ressonância Magnética , Vibração
5.
J Chromatogr A ; 1525: 116-125, 2017 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-29061473

RESUMO

While important advances have been recently achieved in the optimization of lipid classes' separation, information on the specific determination of medium polarity lipids such as sphingolipids (SLs) in highly complex matrices remains fragmentary. In human, disorders of SL metabolism known as sphingolipidoses are a heterogeneous group of inherited disorders affecting primarily the central nervous. Early diagnosis of these conditions is of importance notably when a corrective therapy is available. The diagnosis is generally based on the determination of specific SLs in plasma and red blood cells (RBCs). For instance, glucosylceramide (GL1), glucosylsphingosine (Lyso-GL1), sphingosine (Sph), and sphingosine-1-phosphate (S1P) are proposed as relevant biomarkers for Gaucher disease (GD). Our main objective was to evaluate these biomarker candidates in a cohort of GD patients. However, most of current methods of GL1, Lyso-GL1, Sph, and S1P determination in plasma of GD patients require at least two liquid chromatographic runs. On the other hand, except for GL1 nothing is known concerning the RBC sphingolipid content. Yet, several reversed phase LC-MS methods of SLs separation and/or determination in various media with different sample preparation approaches have been proposed since 2010. Here we focused on stationary phase selection and mobile phase composition as well as on the sample preparation step to optimize and validate an UHPLC-MS/MS method for the simultaneous quantification of the four sphingolipids in both plasma and RBCs. A comparison between seven stationary phases including two RP18, two polar embedded RP18, and three HILIC phases shows that under our conditions polar embedded RP18 phases are the most appropriate for the separation of the four SLs, in terms of efficiency, peak symmetry, and separation time. In the same way, a comparison between a single step extraction with methanol and a liquid-liquid extraction with a mixture of methanol/methyl tert-butyl ether, shows that the latter mixture is the most appropriate for the extraction of SLs in terms of recovery and absence of matrix effect. After validation, this method was applied to the evaluation of the targeted SLs in a cohort of 15 known GD patients. The obtained results show that Lyso-GL1 is the only relevant biomarker in both plasma and RBCs for GD diagnosis. As the proposed method is applicable to the determination in such a highly complex matrices of four SLs with a large difference in polarity, and as the sample preparation procedure is freedom of matrix effects, this method can be easily adapted to a large diversity of samples.


Assuntos
Biomarcadores , Eritrócitos/química , Doença de Gaucher/diagnóstico , Plasma/química , Esfingolipídeos/análise , Esfingolipídeos/sangue , Biomarcadores/análise , Biomarcadores/sangue , Cromatografia Líquida de Alta Pressão , Cromatografia Líquida/métodos , Doença de Gaucher/sangue , Humanos , Extração Líquido-Líquido , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem
7.
J Mass Spectrom ; 43(2): 204-15, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17902194

RESUMO

The analytical performances of two triple-quadrupole instruments, which differ in their atmospheric-pressure sources, were evaluated for native amino acid analysis. The Applied Biosystems/Sciex API 300 instrument was equipped with a turboIon Spray source and a curtain gas interface while the Waters/Micromass Quattro Ultima instrument was characterized by its Z-spray source. Liquid chromatography/mass spectrometry analysis of native amino acids requires volatile ion-pairing mobile phase additives (mainly perfluorinated carboxylic acids). The effects of the structure and concentration of the ion-pairing reagents as well as the organic modifier percentage on the electrospray response of amino acids were studied in detail. The most favourable chromatographic conditions depend strongly on the mass spectrometer used. Several instrumental parameters were also studied, including spray voltage, transmission lens voltages, temperature of desolvation and auxiliary gas flow rates. The results show substantial qualitative differences depending on the instrument geometry. The quantitative performances of the two triple-quadrupole mass spectrometers were evaluated in terms of limits of detection and quantification. The effects of the matrix on the analyte ionization were also examined, and the long-term stability of the electrospray performance was studied over 12 h using a mobile phase containing the perfluorinated ion-pairing reagents. The study provides information on the robustness of the MS instrument and its detection sensitivity towards native amino acid analysis. It appears that each instrument has its good and bad points since one provides higher sensitivity while another is more robust.


Assuntos
Aminoácidos/química , Cromatografia Líquida de Alta Pressão , Espectrometria de Massas por Ionização por Electrospray/instrumentação , Espectrometria de Massas por Ionização por Electrospray/métodos , Pressão Atmosférica , Sensibilidade e Especificidade
8.
J Chromatogr A ; 1157(1-2): 462-6, 2007 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-17517419

RESUMO

The retention behaviour of several triacylglycerols (TAGs) and fats on Hypercarb, a porous graphitic carbon column (PGC), was investigated in liquid chromatography (LC) under isocratic elution mode with an evaporative light scattering detector (ELSD). Mixtures of chloroform/isopropanol were selected as mobile phase for a suitable retention time to study the influence of temperature. The retention was different between PGC and non-aqueous reversed phase liquid chromatography (NARP-LC) on octadecyl phase. The retention of TAGs was investigated in the interval 30-70 degrees C. Retention was greatly affected by temperature: it decreases as the column temperature increases. Selectivity of TAGs was also slightly influenced by the temperature. Moreover, this chromatographic method is compatible with a mass spectrometer (MS) detector by using atmospheric pressure chemical ionisation (APCI): same fingerprints of cocoa butter and shea butter were obtained with LC-ELSD and LC-APCI-MS. These preliminary results showed that the PGC column could be suitable to separate quickly triacylglycerols in high temperature conditions coupled with ELSD or MS detector.


Assuntos
Cromatografia Líquida/métodos , Grafite/química , Temperatura Alta , Triglicerídeos/análise
9.
J Chromatogr A ; 1081(2): 174-81, 2005 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-16038207

RESUMO

A new procedure based on hydrophilic interaction chromatography coupled to tandem mass spectrometry (ionisation process by pneumatically assisted electrospray in negative ion mode), is developed and validated for the simultaneous determination of underivatised taurine and methionine in beverages rich in carbohydrates such as energy drinks. No initial clean-up procedure and no sample derivatisation are required. Satisfactory analysis was obtained on an Astec apHera NH2 (150 mm x 4.6 mm; 5 microm) column with methanol-water (60/40) as mobile phase. The method was validated in terms of specificity, detection limits, linearity, accuracy, precision and stability, using threonine as internal standard. The potential effects of matrix and endogenous amino acid content were also examined. The limits of detection in the beverage varied from 20 microg L(-1) for taurine to 50 micro L(-1) for methionine.


Assuntos
Bebidas/análise , Cromatografia Líquida/métodos , Metionina/análise , Espectrometria de Massas por Ionização por Electrospray/métodos , Taurina/análise , Carboidratos da Dieta , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...